Hlorogen H1000

hlorogen_mali150Hlorogen is device for electrolytic production of chlorine in the form of sodium hypochlorite (NaOCl) solution.
Capacity is 1 kg/h or 24 kg/day of equivalent chlorine.

Since no gaseous chlorine is present, water chlorination is absolutely safe due to system design. For production of sodium hypochlorite solution all that is needed is  common salt,  softened  water and electric energy. Production expenses are up to two times lower compared  to gaseous chlorine disinfection, or commercial sodium hypochlorite.

System is easy to use, demands only minimal maintenance and it is fully automated. Exploitation period is minimum 20 years.

Characteristics of the system

Hlorogen H1000 – Characteristics of the system

E1000 electrolyzers capacity to produce 1000g/h, 24.0 kg/day is sufficient to disinfect the water with flow of 556 l/s in order to maintain the 0.5 mg/l residual prescribed by law.

Maximum water flow that can be disinfected with Hlorogen H1000, depending on chlorine needs and desired residuals

 

Chlorine need (mg/l)

Desired chlorine residual (mg/l)

Chlorine consumption (g/min))

NaOCl consumption (ml/min)

Chlorine consumption (g/h)

NaOCl consumption (l/h)

Maximal water flow (l/s)

0

0,3

16,67

1667

1000

100

926

0

0,4

16,67

1667

1000

100

695

0

0,5

16,67

1667

1000

100

556

0,1

0,5

16,67

1667

1000

100

463

0,2

0,5

16,67

1667

1000

100

397

0,3

0,5

16,66

1666

999

99,9

347

0,4

0,5

16,63

1663

998

99,8

308

0,5

0,5

16,62

1662

997

99,7

277

0,6

0,5

16,63

1663

998

99,8

252

0,7

0,5

16,63

1663

998

99,8

231

0,8

0,5

16,61

1661

997

99,7

213

0,9

0,5

16,63

1663

998

99,8

198

1

0,5

16,65

1665

999

99,9

185

1,2

0,5

16,63

1663

998

99,8

163

1,4

0,5

16,64

1664

999

99,9

146

1,6

0,5

16,63

1663

998

99,8

132

1,8

0,5

16,56

1656

994

99,5

120

2

0,5

16,65

1665

999

99,9

111

2,2

0,5

16,52

1652

991

99,1

102

2,4

0,5

16,53

1653

992

99,2

95

2,6

0,5

16,55

1655

993

99,3

89

2,8

0,5

16,63

1663

998

99,8

84

3

0,5

16,59

1659

995

99,5

79

3,5

0,5

16,56

1656

994

99,4

69

4

0,5

16,47

1647

988

98,8

61

4,5

0,5

16,5

1650

990

99

55

5

0,5

16,5

1650

990

99

50

 

 

Technical Data

This content is for our users only. Register here. If you already have an account, you can log in here.
 

Operation Basics

Hlorogen H1000 – Operation Basics

Water from the pipeline is filling water softener (4), calcium and magnesium ions are removed, and on the outlet of the softened water is obtained. Dosing pump (6) is transferring this water to the electrolyser where it is mixed with sodium chloride solution transferred from tank (3) by means of another dosing pump ( tank 3 contains saturated sodium chloride solution). Electrochemical reaction which results in conversion of sodium chloride into sodium hypochlorite is taking place in the electrolyser cell energized by direct electric current from energetic assembly (35) of the Hlorogen device Hypochlorite solution is stored in the tank (2). Hydrogen generated by conversion reaction is let in to atmosphere by means of ventilating system (28). Optimal hypochlorite production is achieved using system automatic arrangement (36). Sodium hypochlorite solution is injected by dosing membrane pumps (38) into pipeline with water to be disinfected. Residual chlorine analyzer (39) connected into regulation circuit with dosing pump keeps the concentration of residual chlorine in the water on the predetermined level. This is providing continuous production of disinfecting agent, automatic process control and automatic dosing and residual chlorine control.

Full system operation can be monitored through PC (37).

TECHNOLOGICAL SCHEME OF HLOROGEN PLANT

HLOROGEN_tehnoloska_sema

 

Download

This content is for our users only. Register here. If you already have an account, you can log in here.
 
 

Back